AX6700S/AX6600S/AX6300S/AX3800S/AX3600S/AX2400STroubleshooting GuideAX36S-T001X-E0

Pagina 2

iiReading sequence of the manualsThe following shows the manuals you need to consult according to your requirements determined from the following work

Pagina 3 - History of Amendments

3. Troubleshooting Functional Failures During Operation30Default restartPush and hold the RESET button for at least five seconds.Take care when perfor

Pagina 4 - Summary of amendments

3. Troubleshooting Functional Failures During Operation313.4 Stack configuration problems3.4.1 Stack configuration is not possibleIf you cannot config

Pagina 5

3. Troubleshooting Functional Failures During Operation323.4.2 Stack configuration cannot be editedIf you can make a stack configuration but cannot ed

Pagina 6

3. Troubleshooting Functional Failures During Operation333.5 Network interface communication failures3.5.1 Ethernet port cannot be connectedIf it is p

Pagina 7

3. Troubleshooting Functional Failures During Operation34For details about the log, see the manual Message and Log Reference.2. Isolating the cause of

Pagina 8

3. Troubleshooting Functional Failures During Operation35(3) Checking statisticsYou can use the show port statistics command to check the number of se

Pagina 9 - Manual URL

3. Troubleshooting Functional Failures During Operation363.5.3 Actions to be taken for 10BASE-T/100BASE-TX/1000BASE-T problemsIf a 10BASE-T/100BASE-TX

Pagina 10

3. Troubleshooting Functional Failures During Operation37Table 3-10: Failure analysis method for 10BASE-T/100BASE-TX/1000BASE-T problemsNo. Items to c

Pagina 11

3. Troubleshooting Functional Failures During Operation383.5.4 Actions to be taken for 100BASE-FX/1000BASE-X problemsIf a 100BASE-FX/1000BASE-X proble

Pagina 12

3. Troubleshooting Functional Failures During Operation391. Checking the logFor details about the log, see the manual Message and Log Reference.2. Iso

Pagina 13 - AX2400S series switches

iiiAX3800S and AX3650S series switches

Pagina 14

3. Troubleshooting Functional Failures During Operation40Check the cable length. For the cable length, see the Hardware Instruction Manual.Check wheth

Pagina 15

3. Troubleshooting Functional Failures During Operation413.5.5 Actions to be taken for 10GBASE-R/40GBASE-R problemsIf a 10GBASE-R/40GBASE-R problem oc

Pagina 16 - AX2400S series switch

3. Troubleshooting Functional Failures During Operation42Check whether the cables are connected correctly (for example, check for incomplete insertion

Pagina 17

3. Troubleshooting Functional Failures During Operation433.5.6 Actions to be taken for PoE problemsIf a problem such as a disabled power supply unit o

Pagina 18

3. Troubleshooting Functional Failures During Operation44Table 3-13: Communication failure analysis method when PoE is used3.5.7 Communication failure

Pagina 19 - Contents

3. Troubleshooting Functional Failures During Operation45• Port DownThe status of the port is link down. For details, see 3.5 Network interface commun

Pagina 20

3. Troubleshooting Functional Failures During Operation463.6 Layer 2 network communication failures3.6.1 Layer 2 communication by VLANs is not possibl

Pagina 21

3. Troubleshooting Functional Failures During Operation47Execute the show vlan mac-vlan command and make sure the MAC address set for a VLAN by using

Pagina 22 - 7. Device Restart 199

3. Troubleshooting Functional Failures During Operation48port for the transfer.When Snoop is displayed for Type:See 3.6.4 Multicast forwarding by IGMP

Pagina 23 - Safety Information [AX6700S]

3. Troubleshooting Functional Failures During Operation49in the configuration are correct, and that bandwidth monitoring, drop control, or the shaper

Pagina 24

ivAX3640S and AX3630S series switches

Pagina 25

3. Troubleshooting Functional Failures During Operation503.6.3 Failures occurring when the Ring Protocol functionality is usedThis subsection describe

Pagina 26

3. Troubleshooting Functional Failures During Operation51Table 3-16: Failure analysis method for the Ring ProtocolNo. Items to check and commandsActio

Pagina 27

3. Troubleshooting Functional Failures During Operation523.6.4 Multicast forwarding by IGMP snooping is not possibleIf multicast forwarding is not pos

Pagina 28

3. Troubleshooting Functional Failures During Operation53Figure 3-4: Analysis flowchartTable 3-17: Failure analysis method for multicast forwardingNo.

Pagina 29

3. Troubleshooting Functional Failures During Operation543 Make sure the settings for using IPv4 multicast are correct.Check the following:• For AX380

Pagina 30 - Cleaning

3. Troubleshooting Functional Failures During Operation55# If the Switch is the IGMP querier, the same address is displayed for IGMP querying system a

Pagina 31

3. Troubleshooting Functional Failures During Operation56Figure 3-5: Analysis flowchartTable 3-18: Failure analysis method for multicast forwardingNo.

Pagina 32

3. Troubleshooting Functional Failures During Operation573 Make sure the settings for using IPv6 multicast are correct.Check the following:• For AX380

Pagina 33

3. Troubleshooting Functional Failures During Operation58#: If the Switch is the MLD querier, the same address is displayed for MLD querying system an

Pagina 34

3. Troubleshooting Functional Failures During Operation593.7 IPv4 network communication failures3.7.1 Communication is not possible or is disconnected

Pagina 36

3. Troubleshooting Functional Failures During Operation60Figure 3-6: Failure analysis procedure when IPv4 communication is not possible(1) Checking th

Pagina 37 - AX6608S 64 kg

3. Troubleshooting Functional Failures During Operation615. If a log entry was not displayed for the date and time when communication was disabled, se

Pagina 38

3. Troubleshooting Functional Failures During Operation62device is impossible, the address might not have been resolved by ARP. To check the status of

Pagina 39

3. Troubleshooting Functional Failures During Operation63configuration. For details about the procedure, see 3.25.1 Checking the filters and QoS confi

Pagina 40

3. Troubleshooting Functional Failures During Operation64Figure 3-7: Failure analysis procedure on DHCP and BOOTP relays(a) Checking the log and inter

Pagina 41

3. Troubleshooting Functional Failures During Operation651. Log in to the Switch.2. Use the ping command to check the communication with the two remot

Pagina 42

3. Troubleshooting Functional Failures During Operation663. If the routing information obtained by the Switch does not contain the routing information

Pagina 43

3. Troubleshooting Functional Failures During Operation672. The network configuration is changed.3. The DHCP server fails.First, check for cause 1. De

Pagina 44

3. Troubleshooting Functional Failures During Operation684. Check the settings of the device used as the DHCP relay agent. If the Switch is used as th

Pagina 45

3. Troubleshooting Functional Failures During Operation693.7.3 Dynamic DNS link does not work in the DHCP functionality(1) Communication problems on t

Pagina 46

viAbbreviations used in the manual AC Alternating CurrentACK ACKnowledgeADSL Asymmetric Digital Subscriber LineALG App

Pagina 47 - Safety Information [AX6300S]

3. Troubleshooting Functional Failures During Operation702. Make sure that the key information and the authentication key specified on the DNS server

Pagina 48

3. Troubleshooting Functional Failures During Operation71(f) Checking the filters and QoS configuration informationOnly certain packets might have bee

Pagina 49 - AX6308S 64 kg

3. Troubleshooting Functional Failures During Operation723.8 IPv4 unicast routing communication failures3.8.1 No RIP routing information existsIf RIP

Pagina 50

3. Troubleshooting Functional Failures During Operation733.8.3 No BGP4 routing information existsIf BGP4 routing information cannot be found in the ro

Pagina 51

3. Troubleshooting Functional Failures During Operation743.8.4 IPv4 routing information cannot be found in VRFIf the routing information of each proto

Pagina 52

3. Troubleshooting Functional Failures During Operation753.9 Communication failures in the IPv4 multicast routing functionalityThis section describes

Pagina 53

3. Troubleshooting Functional Failures During Operation763 Make sure that PIM-SM is running on one or more interfaces.show ip pim interfaceIf PIM-SM i

Pagina 54

3. Troubleshooting Functional Failures During Operation77(2) Items to check for BSRThe following table shows the items to check when the Switch is use

Pagina 55

3. Troubleshooting Functional Failures During Operation78(4) Items to check for last-hop-routerThe following table shows the items to check when the S

Pagina 56

3. Troubleshooting Functional Failures During Operation79Table 3-27: Items to check for first-hop-router3.9.2 Multicast data is forwarded twice in the

Pagina 57

viiIPv6 Internet Protocol version 6IPV6CP IP Version 6 Control Protocol IPX Internetwork Packet ExchangeISO International

Pagina 58

3. Troubleshooting Functional Failures During Operation80Notes:•first-hop-router: The router that is connected directly to the multicast sender•last-h

Pagina 59 - [AX2400S]

3. Troubleshooting Functional Failures During Operation81(2) Items to check for last-hop-routerThe following table shows the items to check when the S

Pagina 60

3. Troubleshooting Functional Failures During Operation82(3) Items to check for first-hop-routerThe following table shows the items to check when the

Pagina 61

3. Troubleshooting Functional Failures During Operation83Table 3-32: Items to check when data continues to be forwarded twice3.9.5 IPv4 multicast comm

Pagina 62

3. Troubleshooting Functional Failures During Operation843.9.6 Problems that occur during IPv4 multicast communication in the extranetTo resolve probl

Pagina 63

3. Troubleshooting Functional Failures During Operation85Figure 3-12: Example of an IPv4 PIM-DM networkNotes:•first-hop-router: The router that is con

Pagina 64

3. Troubleshooting Functional Failures During Operation86(2) Items to check for last-hop-routerThe following table shows the items to check when the S

Pagina 65

3. Troubleshooting Functional Failures During Operation87IPv4 PIM-DM network configuration.Table 3-37: Items to check for first-hop-router3.9.8 Multic

Pagina 66

3. Troubleshooting Functional Failures During Operation883.10 IPv6 network communication failures3.10.1 Communication is not possible or is disconnect

Pagina 67

3. Troubleshooting Functional Failures During Operation89For details about the contents of the log, see the manual Message and Log Reference.1. Log in

Pagina 68

viiiRA Router AdvertisementRADIUS Remote Authentication Dial In User ServiceRDI Remote Defect IndicationREJ REJect RFC

Pagina 69

3. Troubleshooting Functional Failures During Operation903. If communication with the remote device cannot be verified by using the ping ipv6 function

Pagina 70 - Disposal of a Switch

3. Troubleshooting Functional Failures During Operation91possible, address information might not be correctly distributed by RA. Therefore, check whet

Pagina 71 - 1. Overview

3. Troubleshooting Functional Failures During Operation92Figure 3-14: Failure analysis procedure on IPv6 DHCP relays(1) Checking the log and interface

Pagina 72

3. Troubleshooting Functional Failures During Operation931. Log in to the Switch.2. Use the show ipv6 neighbors command to check the status of address

Pagina 73

3. Troubleshooting Functional Failures During Operation94prefix or address to the target client is set by the ipv6 dhcp relay destination configuratio

Pagina 74

3. Troubleshooting Functional Failures During Operation95(b) Checking the status of the IPv6 DHCP server on the Switch1. Checking whether the IPv6 DHC

Pagina 75 - Redundant power models

3. Troubleshooting Functional Failures During Operation96!(config)#(d) Duplicate assignment to a client1. Checking the binding informationUse the show

Pagina 76

3. Troubleshooting Functional Failures During Operation971. The configuration has been set but not distributed.2. An operation or event has occurred t

Pagina 77

3. Troubleshooting Functional Failures During Operation98Destination Next Hop Interface Metric Protocol Age3ffe:1234:5678::/

Pagina 78 - DUPLEX mode is selected

3. Troubleshooting Functional Failures During Operation993.11 IPv6 unicast routing communication failures3.11.1 RIPng routing information cannot be fo

Pagina 79

ixcurrent vendor, or a switch from another vendor. The context decides the meaning.Conventions: KB, MB, GB, and TBThis manual uses the following conve

Pagina 80

3. Troubleshooting Functional Failures During Operation1003.11.3 No BGP4+ routing information existsIf BGP4+ routing information cannot be found in th

Pagina 81

3. Troubleshooting Functional Failures During Operation1013.11.4 No IPv6 routing information exists in the VRFIf routing information for each protocol

Pagina 82

3. Troubleshooting Functional Failures During Operation1023.12 Communication failures in the IPv6 multicast routing functionalityThis section describe

Pagina 83

3. Troubleshooting Functional Failures During Operation1034 Check whether MLD snooping is set for the interface on which PIM runs.show mld-snoopingIf

Pagina 84

3. Troubleshooting Functional Failures During Operation104(2) Items to check for BSRThe following table shows the items to check when the Switch is us

Pagina 85

3. Troubleshooting Functional Failures During Operation105(4) Items to check for last-hop-routerThe following table shows the items to check when the

Pagina 86

3. Troubleshooting Functional Failures During Operation1063.12.2 Multicast data is forwarded twice in the IPv6 PIM-SM networkIf multicast data is forw

Pagina 87

3. Troubleshooting Functional Failures During Operation107network configuration.Table 3-51: Items checked in commonNo. Items to check and commands Act

Pagina 88

3. Troubleshooting Functional Failures During Operation108(2) Items to check for last-hop-routerThe following table shows the items to check when the

Pagina 89 - >show logging

3. Troubleshooting Functional Failures During Operation109(3) Items to check for first-hop-routerThe following table shows the items to check when the

Pagina 91

3. Troubleshooting Functional Failures During Operation110Table 3-54: Items to check when data continues to be forwarded twice3.12.5 IPv6 multicast co

Pagina 92

3. Troubleshooting Functional Failures During Operation111multicast communication is possible in each VRF. After that, check the following.Table 3-56:

Pagina 93 - During Operation

3. Troubleshooting Functional Failures During Operation1123.13 Layer 2 authentication communication failures3.13.1 Communication failures occurring wh

Pagina 94

3. Troubleshooting Functional Failures During Operation1136 Execute the show dot1x logging command, and check whether authentication failed.• If New S

Pagina 95 - 3.2 Memory card problems

3. Troubleshooting Functional Failures During Operation114For AX3800S, AX3600S, or AX2400S series switches, if communication is not possible on a port

Pagina 96

3. Troubleshooting Functional Failures During Operation115failures.Table 3-58: Communication failure analysis method for IEEE 802.1X3.13.2 Communicati

Pagina 97

3. Troubleshooting Functional Failures During Operation1163 Make sure that the Web server is running. • Execute the following command to check whether

Pagina 98 - Execution example

3. Troubleshooting Functional Failures During Operation1177Use the show web-authentication statistics command to check the communication status with t

Pagina 99

3. Troubleshooting Functional Failures During Operation118Check the following for the configuration related to Web authentication.13 Check whether aut

Pagina 100

3. Troubleshooting Functional Failures During Operation119Table 3-60: Checking the configuration of Web authenticationNo. Items to check Action1 Check

Pagina 101

xiContentsPreface iSafety Information [AX6700S] xvSafety Information [AX6600S] xxviiSafety Information [AX6300S] xxxixSafety Information [AX3800S]

Pagina 102

3. Troubleshooting Functional Failures During Operation120Check the following for the accounting of Web authentication.Table 3-61: Checking the accoun

Pagina 103

3. Troubleshooting Functional Failures During Operation121Table 3-62: Failure analysis method for MAC-based authenticationNo. Items to check and comma

Pagina 104

3. Troubleshooting Functional Failures During Operation122Check the following for the configuration related to MAC-based authentication.Table 3-63: Ch

Pagina 105

3. Troubleshooting Functional Failures During Operation123Check the following for the accounting of MAC-based authentication.Table 3-64: Checking the

Pagina 106

3. Troubleshooting Functional Failures During Operation1243 Execute the show fense server command to check the operating status of the authentication

Pagina 107

3. Troubleshooting Functional Failures During Operation125Check the following for the configuration related to the authentication VLAN.Table 3-66: Che

Pagina 108

3. Troubleshooting Functional Failures During Operation1264 Check the filtering configuration. Make sure that the filters are correctly set between th

Pagina 109

3. Troubleshooting Functional Failures During Operation1273.14 Communication failures in the high-reliability functionality3.14.1 GSRP communication f

Pagina 110

3. Troubleshooting Functional Failures During Operation128Table 3-68: Failure analysis method when state switching fails in a GSRP configurationIn a G

Pagina 111

3. Troubleshooting Functional Failures During Operation1293.14.2 Communication is not possible with the VRRP configuration of IPv4 networksIf communic

Pagina 112

 Relevant productsThis manual applies to the models in the AX6700S, AX6600S, AX6300S, AX3800S, AX3600S, and AX2400S series of switches. Export

Pagina 113

xii3.5.6 Actions to be taken for PoE problems ... 433.5.7 Communication failure

Pagina 114

3. Troubleshooting Functional Failures During Operation130If VLANs and VRIDs for the primary virtual router are the same among devices that make up th

Pagina 115

3. Troubleshooting Functional Failures During Operation1313.14.3 Communication is not possible with the VRRP configuration of IPv6 networksIf communic

Pagina 116 - [Functionality]

3. Troubleshooting Functional Failures During Operation132Table 3-71: Failure analysis method for VRRPNo. Items to check and commands Action1 On the S

Pagina 117

3. Troubleshooting Functional Failures During Operation1337 Execute the show vrrpstatus command with the statistics parameter, and check the reception

Pagina 118

3. Troubleshooting Functional Failures During Operation1343.14.4 Communication is not possible with uplink redundancyIf communication is not possible

Pagina 119

3. Troubleshooting Functional Failures During Operation135Table 3-72: Failure analysis method for uplink redundancyNo. Items to check and commands Act

Pagina 120

3. Troubleshooting Functional Failures During Operation1363.15 SNMP communication failures3.15.1 MIBs cannot be obtained from the SNMP managerMake sur

Pagina 121

3. Troubleshooting Functional Failures During Operation137When using SNMPv3Execute the show snmp-server configuration command, and check whether the i

Pagina 122

3. Troubleshooting Functional Failures During Operation1383.16 Troubleshooting the sFlow statistics (flow statistics) functionalityThe following figur

Pagina 123

3. Troubleshooting Functional Failures During Operation139 Send CounterSample UDP packets: 621 Send failed packets: 0> Note: Make sure that

Pagina 124

xiii3.16.1 sFlow packets cannot be sent to the collector ...1383.16.2 Flow samples cannot be s

Pagina 125

3. Troubleshooting Functional Failures During Operation140 switchport mode access sflow forward ingress <-- sflow forward must be set.!(conf

Pagina 126

3. Troubleshooting Functional Failures During Operation141(1) Checking whether packets are forwardedExecute the show interfaces command, and check whe

Pagina 127

3. Troubleshooting Functional Failures During Operation1423.17 Communication failures in the neighboring device management functionality3.17.1 Neighbo

Pagina 128

3. Troubleshooting Functional Failures During Operation143Table 3-74: Failure analysis method when the OADP functionality is usedNo. Items to check an

Pagina 129

3. Troubleshooting Functional Failures During Operation1443.18 NTP communication failures3.18.1 The Switch cannot be synchronized by using NTPIf the s

Pagina 130

3. Troubleshooting Functional Failures During Operation1453.19 Communication failures in the IEEE 802.3ah/UDLD functionality3.19.1 Port is in inactiva

Pagina 131

3. Troubleshooting Functional Failures During Operation1463.20 Problems due to the redundant configuration of the BCU, CSU, or MSU3.20.1 Active-standb

Pagina 132

3. Troubleshooting Functional Failures During Operation1473.21 Problems due to the redundant configuration of the BSU3.21.1 BSU switchover is not poss

Pagina 133

3. Troubleshooting Functional Failures During Operation1484notconnect The target BSU is not implemented. Make sure that as many BSU boards as the numb

Pagina 134

3. Troubleshooting Functional Failures During Operation1493.22 Problems due to the redundant configuration of the NIF3.22.1 The standby NIF cannot be

Pagina 135

xiv5.4 Collecting information and transferring files by using the "ftp" command on a remote terminal  ...

Pagina 136

3. Troubleshooting Functional Failures During Operation1503.23 Power saving-related problems3.23.1 Scheduling is disabledIf scheduling is disabled, pe

Pagina 137

3. Troubleshooting Functional Failures During Operation1513.24 Packet congestion in CPU processing does not recoverThis section describes how to take

Pagina 138

3. Troubleshooting Functional Failures During Operation152If the packet type is arp, a large number of ARP packets have been received. In this case, a

Pagina 139

3. Troubleshooting Functional Failures During Operation1533.25 Communication failures in filters and QoS configurations3.25.1 Checking the filters and

Pagina 140

3. Troubleshooting Functional Failures During Operation154discard_pkt statistics item displayed for the port input and output queues of the input and

Pagina 141

3. Troubleshooting Functional Failures During Operation1553.26 Access list logging problems3.26.1 Actions to be taken when access list logs are not ou

Pagina 142

3. Troubleshooting Functional Failures During Operation1563.27 DHCP snooping problems3.27.1 Problems related to DHCPIf DHCP cannot distribute IP addre

Pagina 143

3. Troubleshooting Functional Failures During Operation1573.27.2 Problems related to saving the binding databaseIf binding information cannot be inher

Pagina 144

3. Troubleshooting Functional Failures During Operation1583.27.3 Problems related to ARPIf ARP packets are discarded, IPv4 communication is not possib

Pagina 145

3. Troubleshooting Functional Failures During Operation159If there is no problem, go to No. 2.2 Check whether the ip verify source configuration comma

Pagina 146

xvSafety Information [AX6700S]Using AX6700S series switches correctly and safely• This guide provides important information for ensuring safe use of A

Pagina 147

3. Troubleshooting Functional Failures During Operation1603.28 Policy-based routing problems3.28.1 Actions to take when packets are not forwarded in p

Pagina 148

3. Troubleshooting Functional Failures During Operation161#1If you execute the dump bsu command, do not execute any more commands until a log entry is

Pagina 149

3. Troubleshooting Functional Failures During Operation162#The second time you execute the dump policy command, the memory dump file you collected the

Pagina 150

3. Troubleshooting Functional Failures During Operation163target.3. Due to network congestion, communication with the polling monitoring track target

Pagina 151

3. Troubleshooting Functional Failures During Operation164If the track operating status is Init, the track is stopped because it is immediately after

Pagina 152

3. Troubleshooting Functional Failures During Operation1653.29 Policy-based switching problems3.29.1 Actions to be taken when packets are not forwarde

Pagina 153

3. Troubleshooting Functional Failures During Operation166#1If you execute the dump bsu command, do not execute any more commands until a log entry is

Pagina 154

167Chapter4. Troubleshooting Communication Failures Due to a Resource ShortageThis chapter describes communication failures due to a resource shortage

Pagina 155

4. Troubleshooting Communication Failures Due to a Resource Shortage1684.1 MAC address table resource shortage4.1.1 Checking the MAC address table res

Pagina 156

4. Troubleshooting Communication Failures Due to a Resource Shortage169#: This message might be output with log message No. 1 in the above table.If an

Pagina 157

xviIf anything seems wrong, immediately turn off the power.• If smoke or an unusual smell is emanating from the Switch, or if liquid is spilled into t

Pagina 158

4. Troubleshooting Communication Failures Due to a Resource Shortage170#1: For details, see the manual Operation Command Reference.#2: For details, se

Pagina 159

4. Troubleshooting Communication Failures Due to a Resource Shortage1714.2 When a VLAN identification table resource shortage occurs4.2.1 Checking the

Pagina 160

4. Troubleshooting Communication Failures Due to a Resource Shortage172If any of these log messages are output, you cannot set up any additional funct

Pagina 161

4. Troubleshooting Communication Failures Due to a Resource Shortage1734.3 When a resource shortage occurs in shared memory4.3.1 Checking the resource

Pagina 163

175Chapter5. Obtaining Failure InformationThis chapter mainly describes how to obtain failure information.5.1 Collecting maintenance information5.2 Tr

Pagina 164

5. Obtaining Failure Information1765.1 Collecting maintenance informationWhen a fault occurs with the switch during operation, log and dump informatio

Pagina 165

5. Obtaining Failure Information177(2) Maintenance information for AX3800S, AX3600S, and AX2400S series switchesThe following table lists the maintena

Pagina 166

5. Obtaining Failure Information1785.1.2 Collecting failure information by using the "dump" commandIn the AX6700S, AX6600S, and AX6300S seri

Pagina 167

5. Obtaining Failure Information1791. In the active system, execute the dump psp command for the PSP in the active system.2. In the active system, exe

Pagina 168

xviiswitch without grounding could result in electric shock or failures due to electrical noise.• When the Switch is connected to a DC power supply un

Pagina 169

5. Obtaining Failure Information180of NIF number 1 when the BSUs are installed on the BSU numbers 1 and 2 in a redundant BCU environment.1. Log in to

Pagina 170

5. Obtaining Failure Information18111/01 18:18:42 E3 CSU 25070700 2301:000000000000 PSP online dump command executed.4. After the above log informatio

Pagina 171

5. Obtaining Failure Information1822. In the active BCU, execute the dump nif command for all the ports that have failed.Example:The following procedu

Pagina 172

5. Obtaining Failure Information1835.2 Transferring maintenance information filesThis section describes how to transfer files that contain log or dump

Pagina 173

5. Obtaining Failure Information184(2) Transferring log information to a remote terminalFigure 5-2: Transferring log information to a remote terminal&

Pagina 174

5. Obtaining Failure Information185200 EPRT command successful.150 Opening BINARY mode data connection for 'nimd.core'.100% |***************

Pagina 175

5. Obtaining Failure Information186> cd /usr/var/core/> ls <---1interfaceControl.core nodeIn

Pagina 176

5. Obtaining Failure Information1875.3 Collecting information and transferring files by using the "show tech-support" commandYou can use the

Pagina 177

5. Obtaining Failure Information188...

Pagina 178

5. Obtaining Failure Information1895. Specify the destination directory.6. Specify a file name.(3) Use the "remote command" command to use t

Pagina 179

xviiiHandle power cables carefully.• Do not place anything heavy on a power cable. Do not pull, bend, or process a cable. Doing so could damage the ca

Pagina 180

5. Obtaining Failure Information1905.4 Collecting information and transferring files by using the "ftp" command on a remote terminalYou can

Pagina 181

5. Obtaining Failure Information191Figure 5-11: Obtaining the "show tech-support" unicast informationclient-host> ftp 192.168.0.60

Pagina 182

5. Obtaining Failure Information192220 192.168.0.60 FTP server (NetBSD-ftpd) ready.Name (192.168.0.60:staff1): staff1331 Password required for staff1.

Pagina 183

5. Obtaining Failure Information1935.5 Writing data to a memory cardFailure and maintenance information can be written to a memory card. Note, however

Pagina 185

195Chapter6. Line Testing6.1 Testing a line

Pagina 186

6. Line Testing1966.1 Testing a lineIn line tests, what loops back test frames varies depending on the test type. The following figure shows what loop

Pagina 187

6. Line Testing197Date 2006/03/10 00:20:21 UTCInterface type :100BASE-TXTest count :30 Send-OK :

Pagina 188

6. Line Testing198Figure 6-4: Twisted pair cable2. As shown in the following figure, insert the cables into the connector and crimp them by using a cr

Pagina 189

199Chapter7. Device RestartThis chapter mainly describes how to restart the device.7.1 Restarting the device

Pagina 190

xixWhen pressing the button of the basic control unit, do not use anything with a fragile tip, or anything that might become caught in the switch, suc

Pagina 191

7. Device Restart2007.1 Restarting the device7.1.1 Device restartYou can use the reload command to restart the device. Log data is stored when the dev

Pagina 192

7. Device Restart201In step 2, you will be asked whether you want to capture the CPU memory dump. According to the figure above, you do not use any pa

Pagina 193

7. Device Restart202Figure 7-4: Confirmation messages for CPU memory dump capturingAX3800S, AX3600S, and AX2400S series switchesAs an example, the fol

Pagina 194

7. Device Restart203In this step, choose whether you capture the dump.Figure 7-6: Selection of the CPU memory dump typeIn step 2, you will be asked wh

Pagina 195

7. Device Restart204Figure 7-7: Confirmation messages for CPU memory dump capturing

Pagina 196

205AppendixA. Detailed Display Contents of the "show tech-support" Command

Pagina 197

A. Detailed Display Contents of the "show tech-support" Command206A. Detailed Display Contents of the "show tech-support" CommandA

Pagina 198

A. Detailed Display Contents of the "show tech-support" Command20715 /usr/local/diag/pk_tmrd Operating time information (for Version 11.2 an

Pagina 199

A. Detailed Display Contents of the "show tech-support" Command20841 stty -a -f /dev/tty00 Console terminal information YYYY42cat /var/log/c

Pagina 200

A. Detailed Display Contents of the "show tech-support" Command20961 cat /var/tmp/gen/trace/mng_sub.trcConfiguration command trace informati

Pagina 201

xxDo not install the Switch in a dusty or humid location.• Do not install the Switch in a dusty or humid location. Doing so could result in fire or el

Pagina 202

A. Detailed Display Contents of the "show tech-support" Command21084 show channel-group statistics lacpLACP statistics for link aggregationN

Pagina 203

A. Detailed Display Contents of the "show tech-support" Command211106 show dot1x detail Authentication status information on IEEE 802.X auth

Pagina 204

A. Detailed Display Contents of the "show tech-support" Command212129 show ipv6 pim interface (detail)Information on interfaces with IPv6 PI

Pagina 205

A. Detailed Display Contents of the "show tech-support" Command213149 show ip arp inspection statisticsDynamic ARP inspection statistics (fo

Pagina 206 - When using SNMPv3

A. Detailed Display Contents of the "show tech-support" Command214167 show graceful-restart unicastOperating status of restart routers that

Pagina 207

A. Detailed Display Contents of the "show tech-support" Command215185 show web-authentication user commitDisplay of entries registered in th

Pagina 208

A. Detailed Display Contents of the "show tech-support" Command216Legend Y: Displayed; N: Not displayedNote: Parentheses in the Command (dis

Pagina 209

A. Detailed Display Contents of the "show tech-support" Command2177 show cpu days hours minutes secondsCPU utilization YYYY8show memory summ

Pagina 210

A. Detailed Display Contents of the "show tech-support" Command21832 show session Login session information YYYY33/usr/sbin/pstat -t Termina

Pagina 211

A. Detailed Display Contents of the "show tech-support" Command21953 show netstat interface Kernel interface information YYYY54show vlan lis

Pagina 212

xxisupply unit from a Switch, hold the power supply unit tightly. Pulling a power supply unit carelessly from a Switch might cause the power supply un

Pagina 213

A. Detailed Display Contents of the "show tech-support" Command22075 show loop-detection statisticsStatistics on L2 loop detection (for Vers

Pagina 214

A. Detailed Display Contents of the "show tech-support" Command22195 show dot1x detail Authentication status information on IEEE 802.X authe

Pagina 215

A. Detailed Display Contents of the "show tech-support" Command222116 show ipv6 mld interface Information on interfaces with MLD enabledNNYN

Pagina 216

A. Detailed Display Contents of the "show tech-support" Command223137 show ip dhcp snooping logging infoDHCP snooping log information (for V

Pagina 217

A. Detailed Display Contents of the "show tech-support" Command224155 show ipv6 route summary Number of active and inactive routes maintaine

Pagina 218

A. Detailed Display Contents of the "show tech-support" Command225173 show web-authentication loginDisplay of authenticated-user information

Pagina 219

A. Detailed Display Contents of the "show tech-support" Command226Legend Y: Displayed; N: Not displayedNote: Parentheses in the Command (dis

Pagina 220 - 3.23.1 Scheduling is disabled

A. Detailed Display Contents of the "show tech-support" Command2279 /sbin/dmesg Kernel event information YYYY10cat /var/run/dmesg.boot Kerne

Pagina 221

A. Detailed Display Contents of the "show tech-support" Command22835 ls -lTiR /var/tmp/mmi* CLI information file list (for versions earlier

Pagina 222

A. Detailed Display Contents of the "show tech-support" Command22956 show port statistics Port statistics YYYY57show port protocol Protocol

Pagina 223

History of Amendments[Edition 14]Summary of amendments[Edition 13]Summary of amendments[Edition 12]Summary of amendments[Edition 11]Summary of amendme

Pagina 224

xxiiDo not touch the SFP-T during operation and just after operation stops.• During operation (when a link is established), the temperature of the SFP

Pagina 225

A. Detailed Display Contents of the "show tech-support" Command23077 show spanning-tree statisticsSpanning tree statistics NNNY78show vlan d

Pagina 226 - 3.27 DHCP snooping problems

A. Detailed Display Contents of the "show tech-support" Command231100 show ip dhcp snooping logging infoDHCP snooping log information (for V

Pagina 227

A. Detailed Display Contents of the "show tech-support" Command232Legend: Y: Displayed, N: Not displayedNote: Parentheses in the Command (di

Pagina 228

233IndexSymbols"MC not found." is displayed when the memory card is accessed 25Aactions to be taken for 100BASE-FX/1000BASE-X problems 38act

Pagina 229

Index234faults for AX6700S, AX6600S, and AX6300S series switches 16flow samples cannot be sent to the collector 140forgotten login user password 24for

Pagina 230 - AX6700S, AX6600S, or AX6300S

Index235the Switch cannot be synchronized by using NTP 144transferring files using the ftp command 183transferring files using the zmodem command 185t

Pagina 231

xxiiiDo not turn off the power during a software update (while the ppupdate command is executing).• The Switch automatically restarts after the ppupda

Pagina 232

xxivWhen carrying or packing a Switch and its optional modules, wear a wrist strap to protect against static electricity.• Be sure to wear an antistat

Pagina 233

xxvDo not place a Switch where it will be exposed to hydrogen sulfide or salt.• Placing a Switch in an area where sulfides are present, such as a hot-

Pagina 235

xxviiSafety Information [AX6600S]Using AX6600S series switches correctly and safely• This guide provides important information for ensuring safe use o

Pagina 236

xxviiiIf anything seems wrong, immediately turn off the power.• If smoke or an unusual smell is emanating from the Switch, or if liquid is spilled int

Pagina 237

xxixgrounding could result in electric shock or failures due to electrical noise.• When the Switch is connected to a DC power supply unit, always conn

Pagina 238

xxxHandle power cables carefully.• Do not place anything heavy on a power cable. Do not pull, bend, or process a cable. Doing so could damage the cabl

Pagina 239

xxxiWhen pressing the button of the control and switching unit, do not use anything with a fragile tip, or anything that might become caught in the Sw

Pagina 240

[Edition 10]Summary of amendments[Edition 9]Summary of amendmentsCommunication is not possible or is disconnected • The description was changed in acc

Pagina 241

xxxiiDo not install the Switch in a dusty or humid location.• Do not install the Switch in a dusty or humid location. Doing so could result in fire or

Pagina 242

xxxiiinot allow hair or other objects near the ventilation slots. They might be sucked into the Switch, resulting in injury.When moving the Switch, do

Pagina 243

xxxivcable coating, resulting in fire or electric shock.• When connecting or disconnecting the power cable from the outlet, always hold the plug, not

Pagina 244

xxxvincinerate it, or immerse it in water.Cleaning• Remove dust on and around the Switch regularly. In addition to causing the Switch to stop, accumul

Pagina 245

xxxviDo not turn off the power during a software update (while the ppupdate command is executing).• The Switch automatically restarts after the ppupda

Pagina 246 - 5.1.1 Maintenance information

xxxviiWhen carrying or packing a Switch and its optional modules, wear a wrist strap to protect against static electricity.• Be sure to wear an antist

Pagina 247

xxxviiiDo not place a Switch where it will be exposed to hydrogen sulfide or salt.• Placing a Switch in an area where sulfides are present, such as a

Pagina 248 - In the AX6600S series:

xxxixSafety Information [AX6300S]Using AX6300S series switches correctly and safely• This guide provides important information for ensuring safe use o

Pagina 249 - In the AX6300S series:

xlIf anything seems wrong, immediately turn off the power.• If smoke or an unusual smell is emanating from the Switch, or if liquid is spilled into th

Pagina 250

xligrounding could result in electric shock or failures due to electrical noise.• When the Switch is connected to a DC power supply unit, always conne

Pagina 251

[Edition 8]Summary of amendments[Edition 7]Summary of amendmentsItem ChangesAddition of series • A description relating to the addition of AX6600S ser

Pagina 252

xliiHandle power cables carefully.• Do not place anything heavy on a power cable. Do not pull, bend, or process a cable. Doing so could damage the cab

Pagina 253

xliiiWhen pressing the button of the management and switching unit, do not use anything with a fragile tip, or anything that might become caught in th

Pagina 254

xlivDo not install the Switch in a dusty or humid location.• Do not install the Switch in a dusty or humid location. Doing so could result in fire or

Pagina 255

xlvnot allow hair or other objects near the ventilation slots. They might be sucked into the Switch, resulting in injury.When moving the Switch, do no

Pagina 256 - 2. Transfer the log file

xlvicable coating, resulting in fire or electric shock.• When connecting or disconnecting the power cable from the outlet, always hold the plug, not t

Pagina 257

xlviiincinerate it, or immerse it in water.Cleaning• Remove dust on and around the Switch regularly. In addition to causing the Switch to stop, accumu

Pagina 258

xlviiiDo not turn off the power during a software update (while the ppupdate command is executing).• The Switch automatically restarts after the ppupd

Pagina 259

xlixWhen carrying or packing a Switch and its optional modules, wear a wrist strap to protect against static electricity.• Be sure to wear an antistat

Pagina 260

lboth devices. If you hear noise on the TV or radio, do the following:1. Place the Switch as far away as possible from the TV or radio.2. Adjust the o

Pagina 261

liSafety Information [AX3800S] [AX3600S] [AX2400S]Using AX3800S, AX3600S, and AX2400S series switches correctly and safely• This guide provides import

Pagina 262

[Edition 6]Summary of amendments[Edition 5]Summary of amendments[Edition 4]Summary of amendmentsDetailed display contents of the "show tech-suppo

Pagina 263

liiIf anything seems wrong, immediately turn off the power.• If smoke or an unusual smell is emanating from the Switch, or if liquid is spilled into t

Pagina 264

liiiUse the Switch only with the indicated power supply.• Do not use the Switch at any voltage other than the indicated voltage. Doing so could result

Pagina 265 - 6. Line Testing

livdue to the high output power of EPU-B.Handle power cables carefully.• Do not place anything heavy on a power cable. Do not pull, bend, or process a

Pagina 266 - 6.1.1 Internal loopback test

lvDo not place the Switch in an unstable location.• When installing the Switch on a table, position the Switch horizontally on a worktable strong enou

Pagina 267

lvi• If you must stack multiple Switches during transport, use appropriate packaging. Failure to do so might cause the Switches to become deformed or

Pagina 268

lviiDo not touch the Switch directly if you have a metal allergy.• The Switch is coated with zinc, nickel, gold, and other elements. Do not touch the

Pagina 269 - 7. Device Restart

lviii• Condensation might form on the surfaces and the inside of the Switch if it is moved from a cold location to a warm location. Using the Switch i

Pagina 270 - 7.1.1 Device restart

lixDo not place a Switch in a high-temperature location.• Do not place a Switch in direct sunlight or near a heater or other heat-generating apparatus

Pagina 271

lx• Replacing a fan unit of a redundant power model AX3830STurn off the power before installing or removing a power supply module.• Before installing

Pagina 272

lxiMake sure that you use a valid combination for the direct attach cable and the Switch.The following Switches support SFPP-CU1M/3M/5M. Use the trans

Pagina 273 - Restart OK? (y/n):_

[Edition 3]Summary of amendments[Edition 2]Summary of amendmentsItem ChangesAdditional model • A description relating to the additional model was adde

Pagina 274

lxiiair duster could cause the ferrule tip to become dirty.• Keep the nozzle or container of the air duster from coming into contact with the ferrule

Pagina 275 - Appendix

1Chapter1. OverviewThis chapter provides an overview of failure analysis.1.1 Overview of analyzing failures1.2 Overview of analyzing failures of all o

Pagina 276

1. Overview21.1 Overview of analyzing failuresUse this manual when there is a problem in an AX6700S, AX6600S, AX6300S, AX3800S, AX3600S, or AX2400S se

Pagina 277

1. Overview31.2 Overview of analyzing failures of all or part of the Switch1.2.1 Failure analysis for AX6700S, AX6600S, and AX6300S series switchesIf

Pagina 278

1. Overview4#1: The BCU, CSU, or MSU can be turned off by the Inactivate operation from the system operation panel or by entering a command from the o

Pagina 279

1. Overview51.2.2 Failure analysis for AX3800S, AX3600S, and AX2400S series switchesIf a failure occurs during operation and the actual switch can be

Pagina 280

1. Overview6Table 1-2: LED indications, buttons, and connectorsNo.Name Type Status LEDbrightnessDescription1 PWR LED: Green Power supply status Green

Pagina 281

1. Overview74 MC Connector Memory card slot -- -- Memory card slot5 ACC LED: Green Memory card status ON Regular The memory card is being accessed. (D

Pagina 282

1. Overview811 1-24 LED: Green or orangeOperating status of 10/100/1000BASE-T Ethernet portsGreen Regular Link established, 100 Mbit/s#4, full duplex#

Pagina 283

1. Overview9Legend: --: Not applicable#1: The LED blinks green at long intervals (turns on for 0.5 seconds and off for 5 seconds).#2: This applies whe

Pagina 285

1. Overview101.3 Overview of analyzing failures of functionalityThe following table provides an overview of analyzing functional failures on the Switc

Pagina 286

1. Overview11Spanning tree failure 3.6.2 Failures occurring when the Spanning Tree functionality is usedRing Protocol failure 3.6.3 Failures occurring

Pagina 287

1. Overview12No OSPFv3 information 3.11.2 OSPFv3 routing information cannot be foundNo BGP4+ information 3.11.3 No BGP4+ routing information existsNo

Pagina 288

1. Overview13 Neighboring device information cannot be obtained by the LLDP functionality-- 3.17.1 Neighboring device information cannot be obtained

Pagina 290

15Chapter2. Troubleshooting Switch FailuresThis chapter describes how to take actions when a failure occurs on a Switch.2.1 Troubleshooting faults for

Pagina 291

2. Troubleshooting Switch Failures162.1 Troubleshooting faults for AX6700S, AX6600S, and AX6300S series switches2.1.1 Procedure for handling switch fa

Pagina 292

2. Troubleshooting Switch Failures17Table 2-2: Points to be checked in case of power failures6 The STATUS LED of the BCU, CSU, or MSU is lit in red, t

Pagina 293

2. Troubleshooting Switch Failures182.1.2 Replacing the switch and optional modulesThe procedure to replace the switch and optional modules is describ

Pagina 294

2. Troubleshooting Switch Failures192.2 Troubleshooting faults for AX3800S, AX3600S, and AX2400S series switches2.2.1 Procedure for handling switch fa

Pagina 295

iPrefaceRelevant productsThis manual applies to the models in the AX6700S, AX6600S, AX6300S, AX3800S, AX3600S, and AX2400S series of switches.Before y

Pagina 296

2. Troubleshooting Switch Failures20Table 2-4: Isolating the cause of power failures2.2.2 Isolating the cause of external redundant power unit failure

Pagina 297

2. Troubleshooting Switch Failures21Table 2-5: Isolating the cause of external redundant power unit failuresTable 2-6: Isolating the cause of external

Pagina 299

23Chapter3. Troubleshooting Functional Failures During OperationThis chapter describes what actions to take when a problem occurs, such as when a Swit

Pagina 300

3. Troubleshooting Functional Failures During Operation243.1 Problems related to login passwords3.1.1 Forgotten login user passwordIf a user forgets h

Pagina 301

3. Troubleshooting Functional Failures During Operation253.2 Memory card problems3.2.1 The "show system" or "show mc" command disp

Pagina 302

3. Troubleshooting Functional Failures During Operation263.3 Operation terminal problems3.3.1 Information cannot be entered from the console or does n

Pagina 303

3. Troubleshooting Functional Failures During Operation27Table 3-4: Problems occurring during connection to the modem and action to take3.3.2 Login fr

Pagina 304

3. Troubleshooting Functional Failures During Operation28Table 3-5: Problems occurring during connection to a remote terminal and action to take3.3.3

Pagina 305

3. Troubleshooting Functional Failures During Operation29 2. Use the killuser command to forcibly log out the target user.Specify the login number yo